3.3.3 PuTTY Configuration
Assuming both the CP2102 driver and PuTTY have been installed successfully on the
terminal PC with Microsoft Windows, the user can check the COM port (UART)
number under “COM and LPT” in the “Device Manager”, which can be accessed by
entering the “Control Panel” followed by opening up “System” and then “Hardware”.
Let us assume the CP210x USB to UART Bridge Controller has been assigned with
“COM12”, you can open up PuTTY and begin the configuration as shown below. If
you use the RJ45 (COM1) and a serial port on the terminal PC, please use the COM
port number of that serial port instead of “COM12”.
Specify COM12 under serial line and 115200 for speed, no parity, no flow
control.
Check Serial for connection type.
Click the “Open” button and a PuTTY terminal screen will appear.
Figure 3.3a PuTTY Configuration