9.3.5 UNIT STATUS AND POSITION RESPONSE
TABLE 18: UNIT STATUS AND POSITION RESPONSE
Bit
No
2nd byte 3rd byte 4
th
byte 5
th
byte 6
th
byte
0 1–B; 0-A
1- Tx alarm;
0-Tx O/K
1- Rx Alarm;
0-Rx O/K
Consumption
Current alarm
1-Tx WG SW
Alarm
1
Tx 1-unmute;
0-mute
1-IF-L alarm 1-L-IF alarm
Reflected
power Alarm
1-Rx WG Sw
Alarm
2
Rx 1-unmute;
0-mute
1-L-FR alarm
1-RF–L alarm
1 – TxWG SW
not connected
3
Tx 1- on line
0 – S/B
1-PA temper
alarm
1- LNX current
alarm
1 – RxWG
SW not
connected
4
Rx 1- on line
0 - S/B
1-PA devices
alarm
5
1-Stand Alone
0 -Redundancy
6
1-Unit position
error
7
9.3.6 READ FREQUENCY SHIFT RESPONSE
TABLE 19: READ FREQUENCY SHIFT RESPONSE
Bit
No
2
nd
byte 3
rd
byte 4
th
byte 5
th
byte 6
th
byte
0
1
2
3
4
5
6
7
Frequency
LS byte