9.2 COMMANDS
The following commands are sent from master to slave (Master is a PC, a Control Panel or any
Network Management System (NMS)). The minimum polling time required is 300 ms.
TABLE 13: COMMAND FRAME STRUCTURE
No Description
2nd
byte
3, 4, 5 &6 bytes
Respond. 2,3,4,5,6
bytes.
1 Request condition status 0x01 See TABLE 14
2 Mute/Un-Mute command 0x02
0x5A– mute Tx,
0xA5 - unmute Tx
No Response
8 Set gain 0x05 0x5Axxxx for Tx No Response
5 Read Identification 0x07
See TABLE 15
6 Read serial number 0x08 5 ASCII characters
3
Read RF frequency
ranges
0x09 0x5A for Tx
See TABLE 16
7 Read gain Set. 0x0A 0x5A for Tx
2 &3 &4 bytes –
real gain.
4 Read RF Frequency set 0x0F 0x5A for Tx See TABLE 17
9
Read Hot Spot
temperature
0x12
2, 3 bytes –
temperature.
10
Read available current
consumption
0x13 5,6 bytes- UNIT
11
Read unit status and
switch position
0x23
See TABLE 18
12 Switch WG switches 0x24 0x5A – Tx No Response
13
Read forward and
reflected power levels
0x25
2-3 bytes : FWD
5-6 bytes : REV
14 Read frequency shift 0x27 0x5A – for Tx See TABLE 19