Chapter 4 Command Set 4-211
Chapter 4
4080
@AADI
Example command: @15DI(cr)
response: !1510000(cr)
The counter module at address 15h is instructed to return
digital output data and alarm status. The module responds that
both digital output channels are OFF and alarm state is Momen-
tary
Example command: @05DI(cr)
response: !0530000(cr)
The counter module at address 05H is instructed to return
digital output and alarm status. The module reponds that both
digital output channels are OFF and the alarm status for both
counters are ENABLED.
4080, 4080D
(ADAM-4080D)
(ADAM-4080)