Chapter 4 Command Set 4-51
$AAM
Name Read Module Name
Description The command requests the analog input module at address AA
to return its name
Syntax $AAM (cr)
$ is a delimiter character.
AA (range 00-FF) represents the 2-character hexadecimal
address of the analog input module that you want to
interrogate.
M is the Read Module Name command.
(cr) is the terminating character, carriage return (ODh)
Response !AA(Module Name)(cr) if the command is valid.
There is no response if the module detects a syntax error or
communication error, or if the specified address does not exist.
! is a delimiter character indicating a valid command was
received.
AA (range 00-FF) represents the 2-character hexadecimal
address of an analog input module.
(Module Name) is the name of the module at address AA.
(cr) is the terminating character, carriage return (ODh).
4011, 4011D, 4012, 4013, 4015, 4016,
4017, 4017+, 4018, 4018+, 4018M, 4019
Vista de pagina 134