Chapter 4 Command Set 4-81
Chapter 4
4014D
$AA5
Example command: $135(cr)
response: !13+000.000+200.00(cr)
The module is configured for a ±20mA input current range.
The linear mapping function had been executed and the
mapped input high/low limit values were +200.00 and
+000.00. The command requests the analog input module at
address 13 to return its mapped input limit values for linear
mapping. The addressed module returns the mapped input
high/low limit values at address 13 are +200.00 and +000.00.