Advantech MIC-3369C Guía de instalación Pagina 126

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 161
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 125
Dialogic
®
System Release 6.1 CompactPCI for Windows
®
Release Update 126
Resolved IPY00036504 -- 127 PSTN Call Control Calling gc_MakeCall( ) causes a SETUP message
to be sent. If the first response from the other side is
CONNECTED, the board responds with
CONNECT_ACK, but GCEV_CONNECTED is not
sent to the application. The problem only occurs if
the board is set to Network End; if the board is set to
User End, GCEV_CONNECTED is sent.
Resolved IPY00036347 -- 127 PSTN Call Control QERROR_WARNING messages appear in
Dm3StdErr log. Eventually, gc_SetChanState( )
fails on all channels, and all channels are blocked.
Resolved IPY00036337 -- 125 PSTN Call Control 5ESS did not support CALLED NUMBER TYPE in
the NETWORK_SPECIFIC (0x03) IE for DM3
Boards.
Resolved IPY00036248 -- 135 PSTN Call Control When using Global Call SS7, the 0xb and 0xc
address signals, which were previously reported to
the application as “b” and “c”, are now getting
reported as “#” and “*”, thus breaking backward
compatibility.
Resolved IPY00035451 -- 120 PSTN Call Control WinXP gc_OpenEx( ) fails for device “:N_dkB1T1
for SS7 Board when configured for clear channel.
Resolved IPY00035148 -- 120 PSTN Call Control The gc_Unlisten( ) function has no effect when
issued on “dk” devices using Global Call SS7.
Resolved IPY00034618 -- 120 PSTN Call Control gc_DropCall( ) fails when responding to a
GCEV_DISCONNECT event after a
GCEV_BLOCKED event.
Resolved IPY00034606 -- 123 PSTN Call Control While issuing a make call during a supervised
transfer to a destination that is busy,
gc_ResultMsg( ) function returns with PROTOCOL
ERROR.
Resolved IPY00034254 -- 123 PSTN Call Control gc_SetConfigData( ) function hangs on changing
line encoding/framing at runtime.
Resolved IPY00033163 -- 120 PSTN Call Control Access violation occurs when running ISDN based
application.
Resolved IPY00039492 -- 143 Runtime Trace
Facility (RTF)
RTF logging has a memory leak and drops some
log messages.
Resolved IPY00038894 -- 140 Runtime Trace
Facility (RTF)
RTF logging corrupted device name in dx_close( ).
Issues Sorted By Type, Dialogic
®
System Release 6.1 CompactPCI for Windows
®
(Continued)
Issue Type Defect No.
PTR
No.
SU
No.
Dialogic
®
Product(s) or
Component(s)
Description
Vista de pagina 125
1 2 ... 121 122 123 124 125 126 127 128 129 130 131 ... 160 161

Comentarios a estos manuales

Sin comentarios