Chapter 4
Chapter 4 Command Set
4-9
ADAM-4012 Command Table (Continued)
Command S
y
ntax
Command Name
Command Description
Pa
g
e No.
@AADI Read Digital I/O and
Alarm Status
The addressed module returns the
state of its digital input channel, its
two digital output channels and the
status of its alarm
5-50
@AADO(data) Set Digital Output Set the values of the module's two
di
g
ital outputs
(
ON or OFF
)
5-52
@AAEAT Enable Alarm Enables the alarm in either
Momentary or Latching mode
5-54
@AAHI(data) Set High Alarm Downloads the High alarm limit
value
5-56
@AALO(data) Set Low Alarm Downloads the Low alarm limit
value
5-57
@AADA Disable Alarm Disables all alarm functions 5-58
@
AAC
A
Clear Latch Alarm
The latch alarm is reset
5-59
@AARH Read High Alarm The addressed analog input module
is asked to return its high alarm
value
5-60
@AARL Read Low Alarm The addressed analog input module
is asked to return its low alarm
value
5-61
@AARE Read Event Counter
The addressed module is asked to
return its event counter value
5-62
@AACE Clear Event Counter
The event counter is set to 0 5-63
Vista de pagina 111