81 PCI-1680U/1682U User Manual
Chapter 4 Software Requirements
4.8.1.3 Configure
Users can set values of Baud Rate, Timeout of sending and receiving data, mask of
receive register and filter. Meanwhile, status of the port can be displayed.
Please refer to Configure flow chart for function calling.
Before you begin, please select the name of the port you have installed in combobox
of CAN Port, such as can0, can1, etc. Select value of Baud Rate that you want in
dropdown list of Baud Rate (The default value is 125 k). Select Single or Dual of
Acceptance FIlter Mode. Enter filter mask for receiving data in the fields of Accep-
tance Mask and Acceptance Code (The default value is 0xFFFFFFFF). Type values
of timeout in Write Timeout and Read Timeout fields (The default value is 3000 ms).
After configuring the above items, users can click "Configure" button to change the
current setting of the port.
After clicking "Configure" button, successful message and the new configuration
information will be displayed if you succeed in configuring. In addition, number of
received data and values of controllers will be displayed as well. If the configuration
fail, prompting message will be dispalyed.
WDM
Note! This is only used to change configuration of the application which is cur-
rently running. Once "Configure" item is closed, all changes made in it
will not be retained.