Compliance Certification Services Inc.
Report No.: 40614203-D Date of Issue: July 15, 2004
Page 16 Rev. 00
7.4 TEST RESULTS
Line Conducted Emission
Model: PPC-V106 Test Mode: Mode 1
Temperature: 27°C
Humidity: 60% RH
Tested by: Carl Chang Test Results: Pass
(The chart below shows the highest readings taken from the final data)
L1 = Line One (Live Line) / L2 = Line Two (Neutral Line)
Note: “---” denotes the emission level was or more than 2dB below the Average limit, so no re-check anymore.
Q.P. AVG Q.P. AVG Q.P. AVG
Raw Raw Limit Limit Margin Margin
(dBuV) (dBuV) (dBuV) (dBuV) (dB) (dB)
5.313 50.20 45.60 60.00 50.00 -9.80 -4.40 L1
5.435 47.50 --- 60.00 50.00 -12.50 --- L1
12.626 42.80 --- 60.00 50.00 -17.20 --- L1
13.277 41.20 --- 60.00 50.00 -18.80 --- L1
15.815 38.20 --- 60.00 50.00 -21.80 --- L1
17.653 37.60 --- 60.00 50.00 -22.40 --- L1
5.320 51.50 47.70 60.00 50.00 -8.50 -2.30 L2
5.435 46.30 --- 60.00 50.00 -13.70 --- L2
12.173 41.70 --- 60.00 50.00 -18.30 --- L2
13.477 40.60 --- 60.00 50.00 -19.40 --- L2
14.828 39.20 --- 60.00 50.00 -20.80 --- L2
16.902 38.30 --- 60.00 50.00 -21.70 --- L2
Freq.
(MHz)
NOTE