Compliance Certification Services Inc.
Report No.: 40614203-D Date of Issue: July 15, 2004
Page 11 Rev. 00
7 LINE CONDUCTED & RADIATED EMISSION TEST
7.1 LIMIT
Maximum permissible level of Line Conducted Emission
Class A (dBuV) Class B (dBuV)
Frequency
(MHZ)
Quasi-peak Average Quasi-peak Average
0.15 - 0.5 79 66 66 - 56 56 - 46
0.50 - 5.0 73 60 56 46
5.0 - 30.0 73 60 60 50
Note: The lower limit shall apply at the transition frequency.
Maximum permissible level of Radiated Emission measured at 10 meter
Class A (dBuV/m) Class B (dBuV/m)
Frequency
(MHZ)
Quasi-peak Quasi-peak
30 – 230 40 30
230 - 1000 47 37
Note: The lower limit shall apply at the transition frequency.
Maximum permissible level of Radiated Emission measured at 3 meter
Class A (dBuV/m) Class B (dBuV/m)
Frequency
(MHZ)
Average Peak Average Peak
Above 1000 59.3 79.3 53.9 73.9
Note: The lower limit shall apply at the transition frequency.