4.6.2 CounterEventRead
Reads the current counter total without disturbing the counting process and returns the count and
overflow conditions.
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program..
Counter Counter number of the specified device.
error in A cluster containing error information, such as the
status, code, and source elements that is passed from
a previous linked VI.
Output:
Data type
Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program..
Counts The count value of the specified counter
OverFlow Overflow status of the counter, 1 means overflow,
0 means no overflow.
error out A cluster containing error information. If error in
indicated an error, the status, code, and source
elements of error out have the same values as the
corresponding elements of error in