Advantech SBD75e Series Especificaciones Pagina 30

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 97
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 29
Front Panel Monitoring & Control
Table 3.2: Select Board Menu
Menu Item Operations
Status >
Lists the status of the input and configuration. All parameters in this menu are
read only.
Configure >
Allows configuration of various parameters within the unit.
System Setup >
Allows configuration of card Ethernet address.
3.3.2.1 Status
The Status parameters may be viewed by selecting the Status option from the Select Board
menu. The read-only parameters displayed are detailed in Table 3.3.
Table 3.3: Status Sub-menu
Menu Item Operations
Status >
Internal lock status
Est. SNR :
Estimated Signal to Noise Ratio in dB.
Actual Baud Rate :
The Actual Baud rate which is required to match the incoming bit rate.
Est. Signal Power:
Estimated Signal power in dBm.
Demod Freq:
Received Frequency offset in Hz of the incoming carrier.
Prog Baud Rate:
The Programmed Baud rate.
Prog Bit Rate :
The Programmed Bit rate. This is not always relevant in DVB-S2 when in an
automatic mode or ACM/VCM and there is no conversion factor. This will be
displayed as 0.
Actual Bit Rate:
This is a calculated bit rate from the actual baud rate. In certain S2 modes this
will be displayed as 0 when there is no conversion factor.
Spectrum:
The Spectrum can be inverted or Normal.
Est. EBNO:
Estimated EbNo.
Est. BER:
Estimated BER, this is not available in all modes at present.
BERT BER:
This is an actual BER when used in conjunction with a PRBS source. In normal
operation this will report Unlocked.
3.3.2.1.1 Status
This further option is available from the Status sub-menu but is only required if the is a problem
with acquisition. The parameters available from this selection are displayed in Table 3.4.
Table 3.4: Status: Status Sub-menu
Menu Item Operations
FPGA :
If the FPGA has been programmed correctly it will report OK.
Signal Level:
The signal level will be reported as Low / OK / High.
AGC:
This will report locked or unlocked.
Timing:
This will report locked or unlocked.
Carrier:
This will report locked or unlocked.
SDF:
This is the framing and is not relevant in all modes. This will report locked or
unlocked.
3-4 SBD75e Series Demodulator Installation and Operation Manual
Vista de pagina 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 96 97

Comentarios a estos manuales

Sin comentarios