UNO-2174A/2178A User Manual 16
2.5.3 RS-485 Auto Flow & RS-422 Master/Slave Mode
You can set the “Auto Flow Control” mode of RS-485 or “Master/Slave”
mode of RS-422 by using the SW4 DIP switch for COM A and COM B..
In RS-485, if the switch is set to “Auto”, the driver automatically senses
the direction of the data flow and switches the direction of transmission.
No handshaking is necessary.
In RS-422, if DIP switch is set to “On,” the driver is always enabled, and
always in high or low status.
2.6 LAN: Ethernet Connector
UNO-2174A/2178A is equipped with two Gigabit LAN controllers. The
controller chip used in both model is RTL8111C Ethernet controller that
is fully compliant with IEEE 802.3u 10/100Base-T CSMA/CD standards
and IEEE 802.3ab specification for 1000Mbps Ethernet. The Ethernet
port provides a standard RJ-45 jack on board, and LED indicators on the
front side to show its Link (Green LED) and Active (Yellow LED) status.
Table 2.1: Auto Flow & Slave/Master Selection
SW4 DIP Switch Setting COM Port Mode Selections
(Default)
COM A
RS-422: Slave mode
RS-485: Auto flow control
COM B
RS-422: Slave mode
RS-485: Auto flow control
COM A
RS-422: Master mode
RS-485: N/A
COM B
RS-422: Slave mode
RS-485: Auto flow control
COM A
RS-422: Slave mode
RS-485: Auto flow control
COM B
RS-422: Master mode
RS-485: N/A
COM A
RS-422: Master mode
RS-485: N/A
COM B
RS-422: Master mode
RS-485: N/A