Solution
The PPC-103T currently runs Windows NT, but it is in the process of upgrading to Windows 2000 and XP. Ethernet connection is
used in configuration and file transfer,program updates,and position status monitoring.All voice data is connected to the Switch
via an audio interface module. All systems are equipped with a touchscreen that allows the operator to use the system with a
customized Graphical User Interface.
System
The system block diagram shows how the Switch is connected to the Operator,and how radios,phones and other communications
equipment are accessed.
Introduction
Having previously implemented the PPC-102T in their system,Redflex is once
again usingAdvantech PPC series.This time,they haveselected the PPC-103T
for their Communications Systems Operator Interface for alarmmonitoring and
control,access to voice recorders and other equipment.
Benefits
The benefits of the PPC-103T arethat these units are small and compact,and can be panel mounted.The integrated
unit also reduces cabling.Its rugged specification protects against shock and vibration,making it highly suitable
for military specifications.
Solution
The client integratedAdvantech's PPC-150M,PCL-818 with their sensor and software for measuring cardiac output.The
monitoring system now is adopted by hospitals,health centres and universities in Europe and NorthAmerica.
System
The system block diagram shows how PPC-150M works in the critical care hemodynamic monitoring system in hospitals
and health centers.
Benefits
To System Integrators
Global company,local support
High reliability industrial applications
Correct performance point
Elegant looking products
Medically certified and special safety requirements were met
To Patients
Quicker stabilisation in preparation for surgery
Accurate and instantaneous monitoring of condition during surgery
Reduces unnecessary transfusions
Better diagnosis during recovery
Faster recovery,shorter stay in hospital
To Hospitals and Doctors
Reduces risk to patients
Reduces length of patient stay
Reduces cost of patient monitoring:
Fast to set up (5 mins vs 40 mins for catheter)
Performed whenever required
Introduction
Our client in London is dedicated to researching and developing new technologyfor an established
hemodynamic monitoring market,covering consumable cardiac outputproducts and monitoring
capital equipment markets.
There are several challenges in hemodynamic monitoring.First,monitoring patient's condition
by blood pressure alone isnot good enough.Cardiac output (blood flow measured inlitres/minute)
is the important parameter because that is an accurate indication of oxygen delivery.Besides,
blood pressure isan easy measurement to make,while cardiacoutput is a difficult measurement
to make.Historically patients have been monitored on pressure alone.
Advantech's PPC-150M was selected tomeet requirements of a cardiac output monitoring system
- safe for patient and clinician,accurate,continuous and real-time,useful and easy to interpret
data,quick to set up and easy to use.