Advantech PCA-6012 Manual de usuario Pagina 28

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 76
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 27
PCA-6012 User Manual 18
2.11 Watch Dog Timer (JWDT1) / Infrared (JIR1)/
Hardware Monitor Alarm(JOBS1)
Figure 2.10 Watch Dog Timer (JWDT1) / Infrared (JIR1)/Hardware Monitor
Alarm(JOBS1)
2.11.1 Watchdog timer output (JWDT1)
The PCA-6012 contains a watchdog timer that will reset the CPU in the event the
CPU stops processing. This feature means the PCA-6012 will recover from a soft-
ware failure or an EMI problem. The JWDT1 jumper settings control the outcome of
what the computer will do in the event the watchdog timer is tripped.
2.11.2 Infrared Connector (JIR1)
This 5-pin header is for connecting infrared device connector.
2.11.3 H/W Monitor Alarm (JOBS1)
(JOBS1) is a 2-pin jumper to enable/disable the alarm for on board security events.
Table 2.2: Watchdog timer output (JWDT1)
Function Jumper Setting
N/A
* System Reset
* default setting
1 - 2 closed
123
2 - 3 closed
1 23
Table 2.3: Hardware Monitor Alarm setting
Pin setting Function
Closed Enable OBS alarm
Open Disable OBS alarm
Vista de pagina 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 75 76

Comentarios a estos manuales

Sin comentarios