9-8
Features
Motion Control
All product specifications are subject to change without notice Last updated : January 2005
PCM-3202
Max. 20 Mbps transfer rate
Supports 2 independent AMONet™ RS-485 rings
Supports up to 128 AMONet™ RS-485 slave modules
Easy installation with RJ45 phone jack and LED diagnostics
Max. 100 m (20 Mbps / 32 slave modules) communication distance
Specifications
16-bit PC/104
Number of Rings 2
IRQ Selection 9, 10, 11 or 12
Transmission Speed 2.5, 5, 10 or 20 Mbps with automatic data flow control
Serial Interface Half duplex RS-485 with transformer isolation
Cable Type CAT5 UTP/STP Ethernet cable
Surge Protection 10 kV
Communication Max. 100 m (20 Mbps/64 slave modules)
Distance
Communication Slave 2 Rings with Max. 128 (1 Ring with 64 slaves)
Module Number
Power Consumption +5 V
DC
at 0.5 A typical
Operating Temperature 0 ~ 60° C (32 ~ 140° F)
Introduction
PCM-3202 is a PC/104 interface card which supports two AMONet™ RS-485 master ports, and transfers data between host and slaves directly without any operations in between.
Each port of the master can control up to 2048 I/O points, 64 axes, or a combination of I/O points and axes for motion control. The master ports support up to 20 Mbps transfer rate
and a maximum communication distance of up to 100 meters.
The communication between master and slave is based on a customized RS-485 solution that saves wires, covers a long distance, supports high-speed communication and has
time-deterministic features. The communication interface between master and host PC is accomplished by memory mapping. Various functions can be chosen on the slave modules,
and standard industrial DIN rail mounting design makes it easy to distribute them in the field. The master collects information from slave modules and publishes the information to
its host PC.
Ordering Information
PCM-3202 PC/104 AMONet™ RS-485 Master Card
ADAM-3210 1-Axis Motion Slave Module
ADAM-3211/PMA 1-Axis Motion Slave for Panasonic
®
Minas A
ADAM-3212/J2S 1-Axis Motion Slave for Mitsubishi
®
MR-J2S
ADAM-3213/YS2 1-Axis Motion Slave for Yaskawa
®
Sigma-II
ADAM-3752 32-CH Digital Input Module
ADAM-3754 32-CH Digital Output Module
ADAM-3756 16-CH/16-CH Digital Input/Output Module
ADAM-3758 24-CH/8-CH Digital Input/Output Module
AMONet™ Slave Module Address Number Setting
PC/104 AMONet™ RS-485 Master Card
NO.#Last
Master
NO.#3
NO.#2
Digital I/O Slave Digital I/O Slave Digital I/O Slave Digital I/O Slave
NO. #1
Last slave module needs [ Terminator ] setting
Motion Slave
NO.#Last
NO.#3
NO.#2
NO. #1
Motion SlaveMotion SlaveMotion Slave
NEW
Software
Windows
®
2000/XP WDM driver
Supports BCB/VB/VC++ programming on Windows
®
2000/XP platform with DLL
AMONet EzLink
AMONet EzLink is a Windows
®