ACP-4320 User Manual 28
5.3 Thermal Sensor
There is a thermal sensor mounted on the right-wall plate, close to the rear side of
the chassis. The thermal sensor monitors the in-chassis temperature. When the side
temperature is overheated, the thermal sensor sends a signal to the alarm board and
a continuous alarm will be activated. To stop the alarm beep, press the Alarm Reset
button on the front panel. Figure 5.2 shows the layout of the thermal sensor module.
Figure 5.2 Thermal sensor module layout
The default sensor I.D. number is 1. Users can refer to Table 5.4 Thermal sensor
number setting to adjust the switch.
7
ON ON ON OFF
Note! Please connect the fan connectors in the correct sequence: If two fans
are set on SW1, the correct method to connect them into connectors
FAN1 and FAN2. If the two fans are connected to other fan connectors,
out of sequence, such as FAN1 and FAN3 or FAN2 and FAN3 or FAN3
and FAN4, then the alarm will not function correctly.
Table 5.3: CN1 & CN2, Temperature sensor connector
Pin 1 +5 V
Pin 2 T_SCLK
Pin 3 T_SDAT
Pin 4 GND
Table 5.4: SW1, Thermal sensor I.D. number setting
Sensor I.D. Number SW 1 -1 SW 1 - 2 SW 1 - 3 SW 1 - 4
1 (default) OFF OFF OFF ON
2OFFOFFONON
3 OFF ON OFF ON
4 OFF ON ON ON
5ONOFFOFFON
6 ON OFF ON ON
7ONONOFFON
8ONONONON