24 PCI-1720 User's Manual
5.1 Overview
Making correct signal corrections is important for accurate data
transmissions. Since most data acquisition applications involve some
form of voltage measurement, making a sound signal connection will
also protect your equipment against possible damage. This chapter
shows you how to make proper signal connections to use PCI-1720.
5.2 D/A Voltage Output Connections
PCI-1720 supports four channels of D/A voltage output. Only one
output signal wire is used with each channel. The voltage output is
referenced to a common ground (AGND).
There are three types of voltage output connections:
1. Floating load.
2. Grounded load.
3. Differential load with ground.
They are shown in the following illustrations.
Figure 5-1: Floating-load connection for D/A voltage output
D/A
Internal Side
V
OUT
AGND
External Side
Floating
Load