23 Chapter 3
Figure 3.3: Replacing the filter on both sides of the chassis
3.4 Replacing the power supply
IPC-623 supports various power supply models. Please see details below.
3.4.1 The redundant power supply model
In this configuration, there is a redundant power supply with various (2,
3, or 4) modules, which are front-accessible and hot-swappable. To
change the module, please be sure to open the front door as wide as possi-
ble (to an angle of at least 90 degrees) or users won’t be able to remove
the module easily.
To replace the redundant power supply module, please proceed as below.
1. Open the front door to the limit (to an angle of at least 90 degrees)
2. For the 460 W redundant power supply module, unlock the latch of the
failed module with a coin. Then grab the handle to gently pull it out,
see Figure 3.4.
3. For 570 W or 810 W N+1 redundant power supply modules, turn off
the power switch of the failed power supply module. Then loosen the
screw and grab the handle to gently pull it out.
4. Make sure that the new power supply module is the same rating as the
currently installed one.
5. Slide the power supply module inward until it locks into the right posi-
tion.
6. For the 570 W or 810 W redundant power supply, secure the screw.
7. Return the handle to its original place.