CHAPTER 8
TROUBLESHOOTING
61
SYmDtom Possible Fault Check
Computer hangs up Bad connections bet- Clean wax on golden
when calling driver ween golden fingers fingers
routine and PC slot
On-board firmware Change the switch
address switch setup setup or the softis
not the same as ware
software setup
The firmware address Change the firmware
or I/O address set- or I/O address settings
conflict with tings
other add-on cards
Instrument does not Wrong instrument Instrument address
response address setting
Bad bus connections Check bus data with
bus analyzer
Wrong instrument Verify with instru-
programming sequence ment manual .
Instrument hangs up Instrument output Send instrument a
when sending data control not set OK Selective Device
Clear
Instrument output Use EOL procedure
terminates on wrong to change
characters terminator
Change instrument
terminator if
possible
Vista de pagina 66