PCA-6289 User’s Manual 48
Set WDT Control Register to control the WDT working mode. The initial
value of WDT Control Register is shown as follows:
Follow these instructions to set the register:
1. Select the time-out intervals of WDT (decide the values of D2, D1, D0
in F2 )
Example: If D2~D0 = 0, the time-out interval is 64 seconds.
2. Enable or Disable WDT ( decide D3 value in F2)
i.e. D3=0, Disables WDT
i.e. D3=1, Enables WDT
Note: This register writes to WDT configuration port.