Automatic Switch-off
DLoG Config Manual V3.10 21
8.1.3. Special features of the switch-on/-off options
On DLoG MPC, IPC and ITC the following message is displayed upon activating a
switch-on option with ignition:
Figure 8.2: Automatic switch-on message for DC/AC devices
This information appears for safety's sake each time a switch-on with ignition option is
activated.
Caution:
Property
damage
Switch-on with ignition is only allowed with DC devices; this
blocks AC devices and they cannot be restarted.
8.1.4. Without automatic switch-off
The following symbol will be displayed in the uppermost line of the dialog if the
automatic switch-off option is not available:
All switch-on options are available; when switching off, however, the options with ignition
cannot be selected.
8.1.5. With automatic switch-off
When the automatic switch-off option is available, the following symbol will be
displayed in the dialog:
. When the switch-on option with ignition or always on is
chosen, switching off using the power key is not possible.
If the option Switch-off with power key was previously selected, a corresponding
message is displayed to the user. Then the switch-off option is automatically set to only
by system shutdown and the option with power key cannot be selected.