Advantech ARK-5280 Manual de usuario Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 88
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
ARK-5280 User Manual 6
Boards are 20W, that means the ARK-5280 can only works under the
maximum of ambient temperature of 30°C.
Figure 1.1: PCI Board Power Consumption Limit
Relative humidity 95 % @ 40° C (non-condensing)
Vibration loading during operation
• When system is equipped with Industrial grade Compact Flash Disk:
5Grms, IEC 60068-2-64, random, 5~500Hz, 1 oct./min, 1hr/axis.
• When system is equipped with 2.5-inch hard disk:
1Grms, IEC 60068-2-64, random, 5~500Hz, 1 oct./min, 1hr/axis.
Shock during operation
• When system is equipped with Compact Flash Disk:
50G, IEC 60068-2-27, half sine, 11 ms duration
• When system is equipped with 2.5-inch Hard Disk:
20G, IEC 60068-2-27, half sine, 11 ms duration
EMC Approved: CE, FCC Class A
Safety Approved: UL