EKI-2525P User Manual.doc 4
1.3 Specification
Communications
Compatibility
IEEE 802.3, 802.3u, 802.3x, 802.3af
LAN
10/100Base-TX
Transmission Distance
Up to 100 m
Transmission Speed
Up to 100 Mbps
Interface
Connectors
5 x RJ-45
6-pin removable screw terminal
(power & relay)
LED Indicators
Unit: P1, P2, P-Fail
TX port: Link/Active, Duplex/Collision
Power
Power Consumption
59.1 Watts (Full load with PoE)
Power Input
2 x Unregulated 48 V
DC
Fault Output
1 Relay Output
Mechanism
Dimensions (WxHxD)
37 x 140 x 95
Enclosure
IP30, Metal shell with solid mounting
kits
Mounting
DIN-rail, Wall
Protection
ESD (Ethernet)
4,000 V
DC
Surge (EFT for power)
3,000 V
DC
Power Reverse
Yes
Current Overload Protection
3A@48V
DC
(Re-settable Fuse)
Environment
Operating Temperature
-10 ~ 60

Operating Humidity
5% ~ 95% (non-condensing)
Storage Temperature
-40 ~ 85
