The alarm board is designed to connect with up to 7 fans. User can set the
fan number by adjusting the switch, SW1, on the alarm board.
4.3 Thermal Sensor
There is a thermal sensor mounted on the right-wall plate, close to the
rear side of the chassis. The thermal sensor monitors the in-chassis tem-
perature. When the side temperature is overheated, the thermal sensor
sends a signal to the alarm board and a continuous alarm will be acti-
vated. To stop the alarm beep, press the Alarm Reset button on the front
panel. Figure 4.2 shows the layout of the thermal sensor module. The
default sensor I.D. number is 1. Users can refer to Section 4.4.1 Thermal
sensor number setting (see next page) to adjust the switch.
Figure 4.2: Thermal sensor module layout
Table 4.2: SW1, Fan number setting
Fan
Number
SW 1-1 SW 1- 2 SW 1- 3 SW 1- 4
0 OFF OFF OFF OFF
1 ON OFF OFF OFF
2 (default) OFF ON OFF OFF
3 ON ON OFF OFF
4 OFF OFF ON OFF
5 ON OFF ON OFF
6 OFF ON ON OFF
7 ON ON ON OFF