Compliance Certification Services Inc.
Report No.: 60707201-F Refer No.: 60321204 Date of Issue: July 7, 2006
Page 12 Rev. 00
7.3 TEST PROCEDURE OF RADIATED EMISSION
Procedure of Preliminary Test
l The equipment was set up as per the test configuration to simulate typical usage per the
user’s manual. When the EUT is a tabletop system, a wooden turntable with a height of
0.8 meters is used which is placed on the ground plane. When the EUT is a floor-standing
equipment, it is placed on the ground plane which has a 3-12 mm non-conductive
covering to insulate the EUT from the ground plane.
l Support equipment, if needed, was placed as per ANSI C63.4.
l All I/O cables were positioned to simulate typical usage as per ANSI C63.4.
l The EUT received AC power source, 120V/60Hz, from the outlet socket under the
turntable. All support equipment received power from another socket under the turntable.
l The antenna was placed at 10 meter away from the EUT as stated in ANSI C63.4. The
antenna connected to the Spectrum Analyzer via a cable and at times a pre-amplifier
would be used.
l The Analyzer / Receiver quickly scanned from 30MHz to 1000MHz. The EUT test
program was started. Emissions were scanned and measured rotating the EUT to 360
degrees and positioning the antenna 1 to 4 meters above the ground plane, in both the
vertical and the horizontal polarization, to maximize the emission reading level.
l The test mode(s) described in Item 3.2 were scanned during the preliminary test:
l After the preliminary scan, we found the test mode described in Item 3.2 producing the
highest emission level.
l The EUT and cable configuration, antenna position, polarization and turntable position of
the above highest emission level were recorded for the final test.