ADAM-4571/4570
1/2-port RS-232/422/485
Serial Device Servers
ADAM-4571L/4570L
1/2-port RS-232
Serial Device Servers
User Manual
Vista de pagina 0
1 2 3 4 5 6 ... 69 70

Indice de contenidos

Pagina 1 - User Manual

ADAM-4571/45701/2-port RS-232/422/485Serial Device ServersADAM-4571L/4570L1/2-port RS-232 Serial Device ServersUser Manual

Pagina 2

ADAM-4570 Series User Manual 2Chapter 1 Overview1.1 IntroductionAdvantech's ADAM-4570 series of Industrial Serial Device Servers are a robust

Pagina 3

3 Chapter 1 1.3 SpecificationsLAN• Compatibility: IEEE 802.3, IEEE 802.3u• Speed: 10/100 Mbps, auto-sensing• No. of Ports: 1• Port Connector: 8-

Pagina 4

ADAM-4570 Series User Manual 4Software• Driver Support: Windows 2000/XP/Vista(x86)• Utility Software: Serial Device Server Configuration Utility•

Pagina 5

5 Chapter 1 1.4 Package Checklist1.4.1 ADAM-4571/4571L• 1 x ADAM-4571/4571L Serial Device Server• CD-ROM for utility and manual• 1 x RS-232 loopb

Pagina 6

ADAM-4570 Series User Manual 6

Pagina 7 - Contents

2CHAPTER 2Getting Started

Pagina 8

ADAM-4570 Series User Manual 8Chapter 2 Getting StartedIn this chapter, you will be given an overview of the ADAM-4570 series hardware installation

Pagina 9 - Overview

9 Chapter 2 2.1.2 LED IndicatorsThere are three or four LEDs located on the top panel of ADAM-4570 series, each with its own specific function.Table

Pagina 10 - Chapter 1 Overview

ADAM-4570 Series User Manual 102.1.3 Dimensions (Unit: mm)Figure 2.1: Top PanelFigure 2.2: Front PanelFigure 2.3: Back Panel

Pagina 11 - 1.3 Specifications

11 Chapter 2 2.1.4 StickersIf you forgot the IP addresses of specific ADAM-4570 series or where the host PC is mapped to the ADAM-4570 series port, w

Pagina 12

ADAM-4570 Series User Manual iiCopyrightThe documentation and the software included with this product are copy-righted 2008 by Advantech Co., Ltd. A

Pagina 13 - 1.4 Package Checklist

ADAM-4570 Series User Manual 12Panel MountingThe ADAM-4570 series can be attached to a wall using the included metal brackets. Each bracket comes w

Pagina 14

13 Chapter 2 DIN-rail MountingYou can mount the ADAM-4570 series on a standard DIN-rail. First, using two screws, attach the metal plate to the DIN-

Pagina 15 - Getting Started

ADAM-4570 Series User Manual 14Piggyback StackADAM-4570 series can be stacked as seen in the figure below.Figure 2.6: Piggyback Stack

Pagina 16 - Chapter 2 Getting Started

15 Chapter 2 2.2.2 Network ConnectionThere are two ways to use the 10/100Base-T Ethernet connector located on the ADAM-4570 series:1. For Local Area

Pagina 17 - 2.1.2 LED Indicators

ADAM-4570 Series User Manual 162.2.3 Power ConnectionYou should take the following steps to connect ADAM-4570 series power.1. Connect the power cabl

Pagina 18 - 2.1.3 Dimensions (Unit: mm)

17 Chapter 2 RJ-48DB-9PIN Name DCD RX TX DTR GND DSR RTS CTS RIRJ-48 1 2 3 4 5 6 7 8 9

Pagina 19 - 2.2 Connecting the Hardware

ADAM-4570 Series User Manual 182.3 Configuration Utility InstallationIn order to use a PC and an Ethernet network to control serial devices connect

Pagina 20

19 Chapter 2 4. Carefully read the Software License Agreement, and press "Yes" to continue.5. The Setup program will specify a default inst

Pagina 21 - 13 Chapter 2

ADAM-4570 Series User Manual 207. After setup has copied all program files to your computer, click the <Finish> button to finish the installat

Pagina 23 - 2.2.2 Network Connection

iiiProduct Warranty (2 years)Advantech warrants to you, the original purchaser, that each of its prod-ucts will be free from defects in materials and

Pagina 24 - 2.2.4 Serial Connection

ADAM-4570 Series User Manual 22Chapter 3 Configuration3.1 Serial Device Server Configuration Utility Overview The ADAM-4570 series provides an eas

Pagina 25 - 17 Chapter 2

23 Chapter 3 There are four major areas in the serial device server configuration utility.1. Serial Device Server List Area: All devices will be sear

Pagina 26

ADAM-4570 Series User Manual 243.2 Discovering Your Serial Device Server3.2.1 Auto SearchingAdvantech Serial Device Server Configuration Utility wi

Pagina 27 - 19 Chapter 2

25 Chapter 3 Select the device in this sub-tree. The first tab on the “Configuration Area” shows the summary of “Basic Information” included device t

Pagina 28

ADAM-4570 Series User Manual 26Click on each item, you will entry the configuration page to change the setting. The configuration will be introduced

Pagina 29 - Configuration

27 Chapter 3 3.2.2 Clearing the Device List and Searching AgainYou can click the button on the “Quick Tool Bar”; utility will clear all list device

Pagina 30 - Chapter 3 Configuration

ADAM-4570 Series User Manual 283.2.3 Manual AppendingUsing “Add IP address to Favorite” or “Search a Range of IP addresses” function, you are able t

Pagina 31 - 23 Chapter 3

29 Chapter 3 3.3 Setting Ethernet ParametersThis section explains how to configure the ADAM-4570 series network using this utility so that it can co

Pagina 32 - 3.2.1 Auto Searching

ADAM-4570 Series User Manual 303.4 Setting Serial ParametersThis section explains how to configure the ADAM-4570 series serial communication parame

Pagina 33 - 25 Chapter 3

31 Chapter 3 3.4.1 Basic ConfigurationDescription: You can give a more detailed description on the function of the port for easier management and mai

Pagina 34

ADAM-4570 Series User Manual ivDeclaration of ConformityCEThis product has passed the CE test for environmental specifications when shielded cables

Pagina 35 - 27 Chapter 3

ADAM-4570 Series User Manual 32Data Bits: The ADAM-4570 series provides four options: 5, 6, 7 and 8.Stop Bits: The ADAM-4570 series provides three o

Pagina 36 - 3.2.3 Manual Appending

33 Chapter 3 3.4.2 Operation Mode ConfigurationCOM Redirector Setting:The Advantech serial device servers extend traditional COM ports of a PC to Eth

Pagina 37 - 29 Chapter 3

ADAM-4570 Series User Manual 34Host Idle Timeout (10 to 255 seconds): The "Host Idle Timeout" setting monitors the connection between the

Pagina 38

35 Chapter 3 Round-Robin mode: Enabling “Response Timeout” parameter, the ADAM-4570 series will operate in “Round-Robin mode”. Each serial port suppo

Pagina 39 - 3.4.1 Basic Configuration

ADAM-4570 Series User Manual 36You might select “USDG Mode” as the following figure to change themode of the port to TCP server/client or UDP mode.P

Pagina 40

37 Chapter 3 Command Listen PortEach port has its own command listen port to accept connected request ofother network device. So, the command listen

Pagina 41 - 33 Chapter 3

ADAM-4570 Series User Manual 38• Round-Robin ModeEnabling “Response Timeout” parameter, the ADAM-4571/4570 will operate in “Round-Robin mode”. Each

Pagina 42

39 Chapter 3 3.4.4 Control Mode (USDG Mode) (Only ADAM-4571 and ADAM-4570 support this function)In controlling mode, the ADAM-4571/4570 presents a mo

Pagina 43 - 35 Chapter 3

ADAM-4570 Series User Manual 40Please refer to the Data Mode (USDG Mode) to setup the Data ListenPort, Command Listen Port, and Data Idle Timeout.Ha

Pagina 44

41 Chapter 3 3.4.5 AT Command ListCommand FunctionATDT<IP address> <TCP port> <CR>“Forms a TCP connection to the specified host.Ex:

Pagina 45 - 37 Chapter 3

vSafety Instructions1. Read these safety instructions carefully.2. Keep this User's Manual for later reference.3. Disconnect this equipment from

Pagina 46

ADAM-4570 Series User Manual 423.4.6 Advanced SettingsThe serial device server provides the advanced settings for some special applications which ne

Pagina 47 - 39 Chapter 3

43 Chapter 3 3.5 Security Configuration3.5.1 Accessible FunctionAllow any IP to access:The default option, any host PC can communicate with this ser

Pagina 48

ADAM-4570 Series User Manual 443.5.2 Port MonitorConfiguration utility provides an excellent function that allows monitor-ing the serial ports’ stat

Pagina 49 - 3.4.5 AT Command List

45 Chapter 3 3.6 Fulfilling Administrator FunctionsThe configuration utility provides several administrator settings for easy management and configu

Pagina 50 - 3.4.6 Advanced Settings

ADAM-4570 Series User Manual 463.6.2 Locate Serial DeviceIf there are many serial device servers need your management, you may need to identify whic

Pagina 51 - 3.5 Security Configuration

47 Chapter 3 If you want to disable this function or change the password, click “Change Password” to change the password to default “None” (leave the

Pagina 52 - 3.5.2 Port Monitor

ADAM-4570 Series User Manual 48Then, please power off the serial device server within ten seconds, after reconnecting the power back, the all settin

Pagina 53 - 45 Chapter 3

49 Chapter 3 Select the firmware you want to update.After downloading the firmware completely, click on the “OK” button. The serial device server wil

Pagina 54 - 3.6.3 Lock Device

ADAM-4570 Series User Manual 50

Pagina 55 - 47 Chapter 3

2CHAPTER 4Setting the COM Redirector

Pagina 56 - 3.6.5 Upgrading the Firmware

ADAM-4570 Series User Manual vi20° C (-4° F) OR ABOVE 60° C (140° F). THIS COULD DAM-AGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVI

Pagina 57 - 49 Chapter 3

ADAM-4570 Series User Manual 52Chapter 4 Setting the COM RedirectorAdvantech Serial Device Sever Configuration Utility also creates virtual COM por

Pagina 58

53 Chapter 4 The serial ports that can be assigned to virtual COM will be shown in this window. Select the serial ports you wish to map or click the

Pagina 59 - Redirector

ADAM-4570 Series User Manual 544.1.2 Manual MappingRight click the serial device name on the sub-tree of Device Server List area and select the “Man

Pagina 60 - 4.1.1 Auto Mapping

55 Chapter 4 Auto Reconnect Property:Sometimes, the connection between Advantech serial device server and HOST is interrupted by network traffic or p

Pagina 61 - 53 Chapter 4

ADAM-4570 Series User Manual 564.1.4 Remove the Virtual COM PortIf you want to remove the virtual COM port, you can remove them one by one or group

Pagina 62 - 4.1.2 Manual Mapping

57 Chapter 4 4.2 Running Diagnostic TestThe purpose of this test is to make sure the communication from host PC to ADAM-4570 series is OK. If there

Pagina 63 - 55 Chapter 4

ADAM-4570 Series User Manual 58Click “Simple Serial Test” on the Tools menu.Select which COM port you want to run diagnostic test, and then press “T

Pagina 64

59 Chapter 4 Signal Test• RTS -> CTS check the RTS and CTS signal between two ports• DTR -> RI check the DTR and RI signal between two ports•

Pagina 65 - 4.2 Running Diagnostic Test

ADAM-4570 Series User Manual 60

Pagina 66

2 APPENDIX APin Assignments

Pagina 67 - 59 Chapter 4

vii Table of ContentsContentsChapter 1 Overview ... 21.1 Introduction ...

Pagina 68

ADAM-4570 Series User Manual 62Appendix A Pin AssignmentsA.1 RS-232 Pin AssignmentsA.2 RJ-48 Cable PIN AssignmentA.2.1 1. RS-422A.2.2 2. RS-485Pin

Pagina 69 - Pin Assignments

ADAM-4570 Series User Manual viii3.4.6 Advanced Settings ..... 423.5 Security Configuration ...